DC 레귤레이트 전원을 사용할 경우 전원은 전압 출력과 전류 출력을 모두 가지고 있지만 다시 전압을 조정하면 전압을 올릴 수 없습니다. 또는 전원 공급 장치에는 전압 출력과 전류 출력이 있습니다. 전류를 높이려면 전류가 많이 조정되지 않습니다.
This is because the operator is not clear about the concepts of "constant voltage" and "constant current". If the "constant voltage" light is on, it means that the power supply is working in a constant voltage state (it can be considered that the voltage is in the active position), and the output current at this time is determined by the load, not by the operator (it can be said that the current accounts for Passive status), if you turn the "Current Adjustment" knob to the right at this time, the current will not increase. But at this time, turn the "Voltage Adjustment" knob to the right, the output voltage will increase, and the output current will also increase accordingly. (Voltage is master, current is slave).
Similarly, if the "constant current" light is on, it means that the power supply is working in a constant current state, and the output voltage at this time is not "adjusted", but determined by the load. Only by adjusting the "current adjustment" knob, the output current will change, and the output voltage will also change. (here current is master and voltage is slave)
In short, to clarify the master-slave relationship. The voltage and current on the load can be changed only when the power supply is in the "constant current" state to adjust the current, and when the power supply is in the "constant voltage" state to adjust the voltage.
Professional Manufacture of DC power supply Contact: MS Judy yan
Whatsapp/Wechat/Mob.: 86-18822802390
스카이프: 86-13923403246
이메일: Marketing@gvdasz.com